Control Devices for Metering and Batching Equipment
SD-02 Control System
SD-02 control system within a continuous weighing batcher is aimed at providing volumemetric and gravimetric batching of bulk and fluid materials as per setup metrological parameters.
Operation Features
Basic Parameters for SD-02 Control System within Continuous Weighing Batcher
Limits of permissible error for batchers as per maximum performance provided that the batcher operates continuously for at least 6 minutes
|
±0.5
|
Supply voltage of monophase alternate current with frequency 50.0±0.5, V
|
from 187 to 242
|
Power demand, W, not exceeding
|
50
|
Ambient temperature, ºС
|
from -10 to +35
|
Dust-proof-and-moisture-proof class of the cabinet (as requested)
|
IP54 (IP65)
|
|
SD-02 System Provides the Following Functions:
- Manual charge of hopper batchers up to upper lever with batcher actuators stopped
- Charging hopper batchers with preset capacity
- Viewing archives for hour, shift, total run
- Receipt and processing of signals from strain sensors and control of batching device actuators for bulk and fluid material batching through gravimetric and volumetric methods basing on processed data
- Control of several batching devices simultaneously basing on Customer's requirements
- Receipt and processing of digital signals on the motor of agitator and discharge units being ready
- Generating digital signals for control of an agitator, dumping device, for SD-02 control system being ready for operation
- Exchanging data with the upper level computer through interface CAN, RS-485 (Modbus RTU data exchange protocol)
|
Design
SD-02 is a modular unit allowing to configure the system as per specific needs of certain equipment for PCS and to be installed into a cabinet. The class of dust and moisture protection of the cabinet is not lower than IP43.
|
Operation Features
Feature
|
Acceptable value
|
Min
|
Nom
|
Max
|
Features Provided within a Continuous Weigh Hopper
|
Maximum performance depending on batcher design, t/h
|
0.1
|
-
|
10.0
|
Minimum performance out of NPP, %
|
10
|
-
|
-
|
Climatic Variables
|
Air pressure, kPa
|
84
|
-
|
107 |
Relative humidity, %
|
30
|
-
|
80
|
Parameters of Digital Inputs
|
Low-level voltage, V
|
0
|
-
|
8
|
- logical one level, V
|
16
|
-
|
30
|
Duration of input signal, ms
|
50
|
-
|
-
|
Parameters of Digital Outputs
|
Switching voltage, V
|
-
|
-
|
30
|
Load current, A
|
-
|
-
|
0.5
|
Parameters of Analogue Strain Metering Channel
|
Load resistance (from 1 to 4 sensors connected in parallel), Ohm
|
95
|
380
|
-
|
Output voltage for sensor feeding, V
|
±5.7
|
±6.0
|
±6.3
|
|
Batcher Operation Principle
|
where P - quantity of materials in the bin
|
Components of SD-02 Control System
SD-02 Schematic Block Diagram
|
|
|
|
|
|