Control Devices for Metering and Batching Equipment
BV-02 Weighing Module
BV-02 weighing module is aimed for discontinuous batching and static weighing within truck, railroad and platform scales.
Operation Features
- Generating highly stable alternating supply voltage for two metering channel, each of them can include from 1 to 4 strain sensors
- Signal smoothing (filtration) of each channel within ranges to be setup
- Setting up function of digital inputs/outputs (zero, tare, weighing, operation, weight change)
- Selecting active input/output levels
- Displaying state and operation of CAN, RS-232 interfaces and state of discrete outputs
Examples of BV-02 Application
|
Basic Features
Relative error in weight metering out of the maximum weighing limit (NPV), %
|
±0.02
|
Power supply from direct current source, V
|
from 18 to 36
|
Power demand, W
|
up to 10
|
Ambient temperature, ºС
|
from -40 to +50
|
Class of dust and moisture protection
|
IP20
|
|
BV-02 Performs the Following Functions as per In-Built Algorithm:
- Receiving signal from each metering channel and its conversion by 24-bit AD converter
- Signal linearization for each metering channel
- Zero setting and scales tare offset
- Automatic calibration
- Calibration of signal for each metering channel
- Metering weight independent for each channel
- Transfer of processed data from strain sensor, digital inputs and outputs to the upper level device through CAN interface by Modbus protocol
|
Design
BV-02 is designed in OKW casing of RAILTEK serial # B6505115.
BV-02 unit is provided with
- two independent galvanically isolated weight metering channels - four galvanically isolated discrete inputs (two for each channel) - four galvanically isolated digital outputs (two for each channel)
Dimensions of unit BV-02: 157mm х 86mm х 58.5mm (width, height, depth) Weight of BV-02 unit without package: 0.3 kg
|
Operation Limits
Feature
|
Acceptable value
|
Min
|
Nom
|
Max
|
General Features
|
Ambient temperature, °С
|
-40
|
-
|
+50
|
Air pressure, kPa
|
84
|
-
|
107
|
Relative humidity, %
|
35
|
-
|
95
|
Parameters of Digital Inputs
|
Low-level voltage, V
|
0
|
-
|
6
|
- logical one level, V
|
12
|
-
|
30
|
Parameters of Digital Outputs
|
Incoming AC voltage, V
|
-
|
-
|
60
|
Commutated direct / alternating current, A
|
-
|
-
|
0.5
|
Parameters of Analogue Strain Metering Channel
|
Number of metering channels, ea
|
-
|
-
|
2
|
Load resistance (from 1 to 4 sensors connected in parallel), Ohm
|
95
|
380
|
-
|
- input voltage, V
|
-6
|
-
|
6
|
Parameters of Output Analogue Signal
|
Output amperage, mA
|
4
|
-
|
20
|
|
|
|
|
|
|