IVK MicroTEK-11
Associated gas controller IVK MicroTEK-11 provides metering, calculation, indication and recorded parameters archiving as well as control over metering system operation modes in the performance of gas accounting.
Associated gas controller is aimed for operation with the wide range of primary equipment of various metering techniques, including the following:
- pressure differential transducers
- vortex transducers
- turbine / rotary transducers
- ultrasound transducers
- coriolis flow transducers
IVK MicroTEK-11 is registered in the State Registers for ME of RF and Republic of Kazakhstan and provided with the Type Approval Certificate for Measuring Equipment (ME), measuring and calibration techniques and the Associated Petroleum Gas Computing Algorithm Certifiication.
|
Features
- configurable software, parameters can be set up through USB port
- in-built web server
- standard RS-485 Modbus RTU and Ethernet Modbus TCP/IP interfaces, USB simplifying the controller integration into the control and recording system of the whole facility
- in-built spark proof circuits, not generating extra error, providing the required accuracy of metering
|
|
|
Basic Features
Parameter
|
Value
|
Measuring channels parameters
|
Standardized current signal measuring channel:
|
Measuring range, mA
|
4..20
|
Maximum number of channels in IVK, pcs
|
38
|
Temperature sensor signal measuring channel:
|
Temperature range, °С:
|
|
- Copper thermoresistance (NSC TSM-50, TSM-100 as per GOST 8.625-2006)
|
from -100 to +100
|
- Copper thermoresistance (NSC TSM-50, TSM-100 as per GOST 8.625-2006)
|
from -100 to +100
|
Maximum number of channels in IVK, pcs
|
1
|
Pulse-frequency signal measuring channel:
|
Measuring range, Hz
|
1..10 000
|
Signal amplitude range, V
|
0.03…30
|
Maximum number of channels in IVK, pcs
|
2
|
Metrologic Parameters
|
Limits for absolute permissible error of metering:
|
Standardized current signal, mA
|
±0.015
|
Thermal converter signal, °С
|
±0.1
|
Limits for relative permissible error of metering:
|
Pulse quantity, %
|
±0.05
|
Pulse quantity, not more than, %
|
±0.025
|
Limits for relative permissible error to convert input electric signals into actual values:
|
Gas volume, %
|
±0.05
|
Gas volume, %
|
±0.05
|
Technical Parameters
|
AC voltage, V
|
110..240
|
Operation temperature ranges, °С
|
from 0 to 50
|
Dimensions (WхHхD), mm
|
100x103x109.5
|
Weight, kg
|
0.5
|
Fastening
|
DIN-35 bar
|
|
|
|