IVK MicroTEK-11

Associated gas controller IVK MicroTEK-11 provides metering, calculation, indication and recorded parameters archiving as well as control over metering system operation modes in the performance of gas accounting.

Associated gas controller is aimed for operation with the wide range of primary equipment of various metering techniques, including the following:

  • pressure differential transducers
  • vortex transducers
  • turbine / rotary transducers
  • ultrasound transducers
  • coriolis flow transducers

IVK MicroTEK-11 is registered in the State Registers for ME of RF and Republic of Kazakhstan and provided with the Type Approval Certificate for Measuring Equipment (ME), measuring and calibration techniques and the Associated Petroleum Gas Computing Algorithm Certifiication.

Features 

  • configurable software, parameters can be set up through USB port
  • in-built web server
  • standard RS-485  Modbus RTU and Ethernet Modbus TCP/IP interfaces, USB simplifying the controller integration into the control and recording system of the whole facility
  • in-built spark proof circuits, not generating extra error, providing the required accuracy of metering
 

Basic Features

Parameter

Value

Measuring channels parameters 

 Standardized current signal measuring channel: 

   Measuring range, mA

4..20

   Maximum number of channels in IVK, pcs

38

 Temperature sensor signal measuring channel:

   Temperature range, °С:

 

       - Copper thermoresistance
       (NSC TSM-50, TSM-100 as per GOST 8.625-2006)

from -100 to +100

       - Copper thermoresistance
       (NSC TSM-50, TSM-100 as per GOST 8.625-2006)

from -100 to +100

   Maximum number of channels in IVK, pcs

1

 Pulse-frequency signal measuring channel: 

   Measuring range, Hz

1..10 000

   Signal amplitude range, V

0.03…30

   Maximum number of channels in IVK, pcs

2

 Metrologic Parameters 

 Limits for absolute permissible error of metering:

   Standardized current signal, mA

±0.015

   Thermal converter signal, °С

 ±0.1

 Limits for relative permissible error of metering: 

   Pulse quantity, %

 ±0.05

   Pulse quantity, not more than, %

 ±0.025

 Limits for relative permissible error to convert input electric signals into actual values:  

   Gas volume, %

±0.05

   Gas volume, %

±0.05

 Technical Parameters

 AC voltage, V

110..240

 Operation temperature ranges, °С

from 0 to 50

 Dimensions (WхHхD), mm

100x103x109.5

 Weight, kg

0.5

 Fastening

DIN-35 bar