Parameters
|
MicroTEK-01 MicroTEK-02 MicroTEK-03 MicroTEK-04 MicroTEK-05 MicroTEK-06
|
MicroTEK-09
|
MicroTEK-11
|
Exterior view
|
|
|
|
Basic functions
|
Metering type
|
|
|
|
Metering product
|
- commercial and crude oil
- associated petroleum gas
- natural gas
- formation water
- routine metering of material flows
|
|
|
Number of metering lines
|
up to 24 metering lines
|
5 metering lines + Block for quality parameters metering (BIK)
|
1 metering line
|
Accordance with normative and technical documentation
|
GOST R 8.595 GOST R 8.615 GOST 8.586.1-5 GOST 30319.1-3 PR 50.2.019 RD 50-411 MI 2667 MI 2693 GSSSD MR 112 GSSSD MR 113 GSSSD MR 122 GSSSD 4 GSSSD 6 GSSSD 8 GSSSD 47 GSSSD 89 GSSSD 109 GSSSD 169 GSSSD 187
|
GOST R 8.595 GOST R 8.615 MI 2693
|
GOST 8.586.1-5 PR 50.2.019 RD 50-411 MI 2667
|
Design
|
Modular product which content depends on object structure.
Supplied as cabinet version (dimensions are determined by order placement). Package supply is available.
|
Construct is designed to be located to 19 inch stand. No expandability is available.
|
Construct is designed to be installed into cabinet on DIN-rail. No expandability is available.
|
Signals received type
|
- frequency/impulse
- analogue
- digital
- signals from HART smart sensors
|
- frequency/impulse
- analogue
- digital
- signals from HART smart sensors
|
- frequency/impulse
- analogue
|
External interfaces
|
- RS-232/RS-485 ModBus RTU
- Ethernet ModBus TCP/IP
|
- RS-232/RS-485
ModBus RTU
- Ethernet ModBus TCP/IP
|
- RS-232/RS-485 ModBus RTU
- Ethernet ModBus TCP/IP
- USB
|
Intrinsic safety limits
|
Built-in into metering modules
|
Built-in
|
Built-in
|
Modes of metrological characteristics inspection and calibration
|
- Standard flow transducer (EPOR/EPMR)
- Calibration unit (TPU, KP, PUMA etc.)
|
- Standard flow transducer (EPOR/EPMR)
- Calibration unit (TPU, KP, PUMA etc.)
|
-
|
Additional Functions
|
Control over automated sampler units with no auxiliary equipment
|
+
|
+
|
-
|
Control over mechanical displacement prover
|
+ |
+ |
- |
Flow control through metering lines and quality assurance unit
|
+ |
+ |
- |
Control over other equipment
|
- stop valves electric drives at metering lines
- pumps
- ventilation
- alarm system
- other actuating devices
|
-
|
-
|
Control over gaseousness at process pads and in premises
|
+
|
-
|
-
|
Field of application
|
|
Multiple metering stations for oil, gas, water and various flows with a great number of metering lines when combination of metering and control over process equipment is required.
|
Current oil metering systems when equipment integration at facilities in operation is required.
|
Systems for current and fiscal metering of associated petroleum gas.
|