IVK MicroTEK-09
Purpose
IVK MicroTEK-09 is aimed for accounting of crude and commercial oil (GOST R 8.595, GOST R 8.615, MI 2693) at the facilities of oil and petroleum industries.
MicroTEK-09 is used for quality and quantity metering of crude and commercial oil for routine and fiscal metering. It can provide metering of up to 5 lines and data processing from oil quality control unit.
|
Features
- designed to be located to 19 inch stand
- in-built spark proof circuits, not generating extra error, providing the required accuracy of metering
- hook up of field equipment with no auxiliary equipment
|
Functions
- receiving and processing frequency, impulse, analogue and discrete signals within metering limits of measuring transducers
- automatic control, indication and signaling about ultimate values of metered parameters
- calculation, indication and transfer of recorded parameters into telemechanics system through RS-485 ModBus RTU, Ethernet ModBus TCP/IP interfaces
- mode for metrological features control and calibration of volume and weight meters as per reference meter
- mode for metrological features control and calibration of volume and weight meters as per calibration unit in compliance with MI 1974, MI 2463
- operation with field sensors through RS-485 Modbus RTU digital interface and HART protocol
- generating oil receipt report, oil data sheet and metering devices changes log
|
|
|
Basic Features
Parameter
|
Value
|
Measuring channels parameters
|
Standardized current signal measuring channel:
|
Measuring range, mA
|
4...20
|
Maximum number of channels in IVK, pcs
|
40
|
Temperature sensor signal measuring channel:
|
Temperature range, °С:
|
|
- Copper thermoresistance (NSC TSM-50, TSM-100 as per GOST 8.625-2006)
|
from -100 to +100
|
- Copper thermoresistance (NSC TSM-50, TSM-100 as per GOST 8.625-2006)
|
from -100 to +100
|
Maximum number of channels in IVK, pcs
|
10
|
Pulse-frequency signal measuring channel:
|
Measuring range, Hz
|
1..10 000
|
Signal amplitude range, V
|
0.06…24
|
Maximum number of channels in IVK, pcs
|
8
|
Metrologic Parameters
|
Limits for absolute permissible error of metering:
|
Standardized current signal, mA
|
±0.015
|
Thermal converter signal, °С
|
±0.05
|
Limits for relative permissible error of metering:
|
Pulse quantity, %
|
±0.025
|
Input frequency, %
|
±0.002
|
Input signal frequency metering channel, %
|
±0.01
|
Ratio of pulse quantity per time interval, %
|
±0.01
|
Limits for relative permissible error to convert input electric signals into actual values:
|
Metering crude and commercial oil volume, %
|
±0.025
|
Metering crude and commercial oil volume, %
|
±0.05
|
Coefficient for volume flow meter, %
|
±0.025
|
Coefficient for weight flow meter, %
|
±0.04
|
Technical Parameters
|
AC voltage, V
|
110...250
|
Operation temperature ranges, °С
|
from +1 to +50
|
Dimensions (width x depth x height), mm
|
483х132х348
|
Weight, kg
|
12
|
Fastening
|
19'' stand
|
Explosion protection marking
|
[Ex ia] IIC
|
|
|
|