russian english german
 

Filtering System

Purpose

It is aimed to remove mechanical impurities and prevent plugging and failure of flow meters and pumps. Filtering system consists of standby line to prevent shutdown of SIKN operation during mainetance. Switching over oil flows between filters can be done manually or automatically.

 

Description

 Permissible differential pressure for plugged filters, not more than, MPa

0.3

 Standard diameters, mm

40, 50, 65, 80, 100, 150, 200, 250, 400, 500

 Nominal pressure, MPa

1.6, 2.5, 4, 6.3, 10

 

Components

Filtering system consists of:

  • Main and standby filters with quick detachable cap
  • Inlet and outlet manifolds, piping with stop valves - manual and automatic
  • Differential pressure sensors and pressure gauges to control pressure differential on filters
  • Drainage system

We use the equipment by the following manufacturers:

  • Filters: BOZNA, Plenty
  • Differential pressure sensors: Emerson, Metran, Yokogawa, JUMO
  • Pressure gauges: Manotom
  • Stop valves: Enerpred-Yardos, GKS, GIRAS, BAZ
  • Electric Drives RemTEK: SME TEC

It is possible to use the equipment by some other manufactures upon the Customer's requirement.

Configuration Options

There could be the following configuration options of the filtering system:

  • Built-in into metering lines
  • As a separate unit
  • On the open pad
  • In the shelter jointly with BIL

If it is implemented as a separate unit, it is more convenient as regards locating, operation, servicing and maintenance.

Our website uses cookies to ensure you get the best experience on our website. By continuing to browse this site you agree to our use of cookies.